Ts42303, Ts42303/1, Ts42304, Ts42305, Ts42306, Ts42307, Ts42308, Ts42308/1, Ts42309

Wattmeters and varmeters Ts42303, Ts42308 are intended for measurement of active or reactive power in three-phase three-wire AC circuits of 50...60 Hz at uniform or non-uniform phase load. Wattmeters Ts42303/1, Ts42308/1 are intended for measurement of active power in one-phase AC circuits of 50, 60, 500, 1000 Hz.
Frequency meters Ts42304, Ts42306, Ts42307 are intended for measurement of AC frequency.
Power factor meters Ts42305 and Ts42309 are intended for measurement of power factor in in three-phase three-wire AC circuits of 50 Hz with symmetry of line voltage and balanced phase load.
The meters are made based on an electronic converter of input signal into DC signal and a moving-coil meter arranged in one case.





Specifications
Documentation
Related products

Type

Ts42307

Ts42308

Ts42306

Ts42303

Ts42303/1

measurand

Hz

kW, MW, GW, kVAr, MVAr, GVAr

Hz

kW, MW, GW, kVAr, MVAr, GVAr

kW, MW, GW,

Overall dimension, mm

80х80

96х96

96х96

120х120

120х120

Panel cutout, mm

Ø77.5

92х92

92х92

112х112

112х112

Scale length, mm, min.

65

97

97

94

94

Accuracy class

1.0

1.5

1.0

1.5

1.5

Weight, kg, maximum

0.25

0.7

0.4

0.9

0.75

Type

Ts42304

Ts42305

Ts42308/1

Ts42309

measurand

Hz

cosφ

kW. MW. GW.

cosφ

Overall dimension. mm

120х120

120х120

96х96

96х96

Panel cutout. mm

112х112

112х112

92х92

92х92

Scale length. mm. min.

94

94

97

97

Accuracy class

0.5

2.5

1.5

2.5

Weight. kg. maximum

0.65

0.75

0.65

0.6

Ts42303, Ts42308 (3-phase mains); Ts42303/1, Ts42308/1 (1-phase mains)

power factor

rated voltage, V

rated current, A

connection method

operation conditions

For wattmeter cosφ=1

For wattmeter sinφ=1

127

220

230*

380

400*

5

Directly

Temperature -40...+50 °С, relative humidity 95 % at temperature +35 °С.

Impact resistance:

acceleration 70 m/s2, frequency 10...50 impacts per min.

Vibration strength:

acceleration 15 m/s2, frequency 30 Hz

1; 5

Via a current transformer

100

1; 5

Via a current/voltage transformer

* – for Ts42308

When ordering wattmeters and varmeters, the following parameters shall be indicated:

1) current transformation factor;

2) voltage transformation factor;

3) frequency of 50 Hz or 60 Hz;

4) balanced or unbalanced load.

Ts42304, Ts42306, Ts42307

measurement range

rated voltage, V

connection method

operation conditions

45...55 Hz 450...550 Hz

350...450 Hz*

127

220

380

230*

400*

Directly

Temperature -40...+50 °С, relative humidity 95 % at temperature +35 °С.

Impact resistance: acceleration 70 m/s2, frequency is 10...50 impacts per min.

Vibration strength: acceleration 15 m/s2, frequency 30 Hz.

100

Via a voltage transformer

* – for Ts42306, Ts42307

Ts42305, Ts42309

measurement range

rated voltage, V

rated current, А

connection method

operation conditions

0.5-1-0.5

0.9-1-0.2

127

220

380

5

Directly

Temperature -40...+50 °С, relative humidity 95 % at temperature +35 °С.

Impact resistance: acceleration 70 m/s2, frequency 10...50 impacts per min. Vibration strength: acceleration 15 m/s2, frequency 30 Hz

100

1; 5

Via a current/voltage transformer

When ordering the power factor meter, the following shall be given:

1) meter type;

2) measurement range;

3) rated voltage and current;

4) standard frequency;

5) specifications designation.

Ordering examples

Wattmeter Ts42303, 220 V, 5 А, 50 Hz, S, TU 25-7504.190-2002

For wattmeter Ts42303 for rated voltage 220 V, rated current 5 A, standard frequency 50 Hz and balanced load.

The same is for a wattmeter manufactured in general climatic conditions:

Wattmeter Ts42303 О4.1, 220 V, 5 А, 50 Hz, S, TU 25-7504.164-2002

Wattmeter Ts42303, 10,000/100, 5000/5, 50 Hz, TU 25-7504.164-2002

For wattmeter Ts42303 with voltage transformation factor 10,000/100, current transformation factor 5000/5, for standard frequency 50 Hz and unbalanced load.

Wattmeter Ts42303/1, 220 V, 5 А, 50 Hz, TU 25-7504.167-2003

For wattmeter Ts42303/1 for rated voltage 220 V, rated current 5 A, standard frequency 50 Hz. The same is for a wattmeter manufactured for operation in general climatic conditions:

Wattmeter Ts42303/1 О4.1, 220 V, 5 А, 50 Hz, TU 25-7504.167-2003

Wattmeter Ts42303/1, 10,000/5, 5000/5 А, 50 Hz, TU 25-7504.167-2003

For wattmeter Ts42303/1 with voltage transformation factor 10,000/100, current transformation factor 5000/5, for standard frequency 50 Hz.

Frequency meter Ts42304, 45...55 Hz, 220 V, v, TU 25-7504.163-2002

For frequency meter Ts42304 having measurement range 45...55 Hz for rated voltage 220 V, vertical operating position. The same is for a frequency meter manufactured for operation in general climatic conditions:

Frequency meter Ts42304 О4.1, 45...55 Hz, 220 V, g, TU 25-7504.163-2002

Ts42305, 0.5-1-0.5, 220 V, 5 А, 50 Hz, TU 25-7504.171-2003

For power factor meter Ts42305 having measurement range 0.5-1-0.5, for rated voltage 220 V, rated current 5 A and standard frequency 50 Hz.

The same is for a power factor meter manufactured in general climatic conditions:

Ts42305 О4.1, 0.5-1-0.5, 220 V, 5 А, 50 Hz, TU 25-7504.171-2003

Frequency meter Ts42306, 45...55 Hz; 220 V, TU 25-7504.181-2005

For frequency meter Ts42306 having measurement range 45...55 Hz for rated voltage 220 V.

The same is for frequency meter Ts42306 manufactured for operation in general climatic conditions:

Frequency meter Ts42306 О4.1, 45...55 Hz; 220 V, TU 25-7504.181-2005

The same is for a frequency meter manufactured meters for marine application:

Frequency meter Ts42306 ОМ2, 45...55 Hz; 220 V, TU 25-7504.181-2005

Wattmeter Ts42308, 220 V, 5 А, 50 Hz, S, TU 25-7504.182-2005

For wattmeter Ts42308 for rated voltage 220 V, rated current 5 A, standard frequency 50 Hz and balanced load. The same is for a wattmeter manufactured for operation in general climatic conditions:

Wattmeter Ts42308 О4.1, 220 V, 5 А, 50 Hz, S, TU 25-7504.182-2005

The same is for a wattmeter manufactured meters for marine application:

Wattmeter Ts42308 ОМ2, 220 V, 5 А, 50 Hz, S, TU 25-7504.182-2005

Wattmeter Ts42308, 1000/100, 5000/5, 50 Hz, TU 25-7504.182-2005

For wattmeter Ts42308 with voltage transformation factor 10,000/100, current transformation factor 5000/5, for standard frequency 50 Hz and unbalanced load.

Wattmeter Ts42308/1, 220 V, 5 А, 50 Hz, TU 25-7504.190-2006

For wattmeter Ts42308/1, rated voltage 220 V, rated current 5 A, standard frequency 50 Hz. The same is for a wattmeter manufactured for operation in general climatic conditions:

Wattmeter Ts42308/1, О4.1, 220 V, 5 А, 50 Hz, TU 25-7504.190-2006

Wattmeter Ts42308/1, 10,000/100, 5000/5, 50 Hz, TU 25-7504.190-2006

For wattmeter Ts42308/1 with voltage transformation factor 10,000/100, current transformation factor 5000/5, for standard frequency 50 Hz.

Ts42309, 0.5-1-0.5, 220 V, 5 А, 50 Hz, TU 25-7504.191-2006

For power factor meter Ts42309 having measurement range 0.5-1-0.5, for rated voltage 220 V, rated current 5 A and standard frequency 50 Hz.

The same is for a power factor meter manufactured in general climatic conditions:

Ts42309, О4.1, 0.5-1-0.5, 220 V, 5 А, 50 Hz, TU 25-7504.191-2006

For reference only:

v/g – vertical/horizontal operating position;

О4.1 – for operation in general climatic conditions;

ОМ2 – meters for marine application (Ts42307, Ts42306, Ts42308).

The procedure of recording in the invoice for analogue meters is given at the end of Section 1 «Electrical Pointer Meters».

Ts42303 Сertificate of conformity (jpg, 1.4 Mb )   View   Download
Ts42303/1 Сertificate of conformity (jpg, 361.9 Kb )   View   Download
Ts42304 Сertificate of conformity (jpg, 1.3 Mb )   View   Download
Ts42305 Сertificate of conformity (jpg, 367.6 Kb )   View   Download
Ts42306, Ts42307 Сertificate of conformity (jpg, 755 Kb )   View   Download
Ts42309 Сertificate of conformity (pdf, 1.6 Mb )   View   Download
Ts42308/1 Сertificate of conformity (1-2017, 1.5 Mb )   View   Download
Ts42308 Сertificate of conformity (jpg, 2 Mb )   View   Download
Ts42303 Manual (pdf, 2.1 Mb )   View   Download
Ts42303/1 Manual (pdf, 319.4 Kb )   View   Download
Ts42305 Manual (pdf, 4.5 Mb )   View   Download
Ts42306, Ts42307 Manual (pdf, 494.3 Kb )   View   Download
Ts42304 Manual (pdf, 1.6 Mb )   View   Download
Ts42308 Manual (pdf, 801.8 Kb )   View   Download
Ts42308/1 Manual (pdf, 456.6 Kb )   View   Download
Ts42309 Manual (pdf, 240 Kb )   View   Download
Ts42306, Ts42307 Has been found to conform to requirements Russian Maritime Register of Shipping (pdf, 352.7 Kb )   View   Download
Ts42308 Has been found to conform to requirements Russian Maritime Register of Shipping (pdf, 370.1 Kb )   View   Download
Back to list